Limited oxygen index tester 5801A
Description :
Put the sample fixed in a transparent combustion cylinder of upward flowing oxygen andnitrogen mixture,ignite top of sample and observe combustion characteristic ,compare the combustion time or sample length to given data,calculate the minium oxygen concentration through the tests at different oxygen concentration.
Standard : GB/T 2406.2-2009
GB/T 5454
ISO 4589-2-2006
ASTM D2863
NES 714
Technology data:
1.) test range:0~100%
2.) working pressure:0.05-0.3Mpa
3.) height of combustion tube:500mm
4.) inner diameter of combustion tube:76mm
5.) Limit flow hole at the top of the combustion tube: Φ 40mm.
6.) Resolution:0.1%
7.) Test precision:+-0.2%
8.) Response time:<200ms
9.) Steady time:<5s
10.) Outter Size:600*520*600
11.) Weight:30kg
Features of machin
1.) Color programmable controller, directly set the oxygen concentratio
2.)Imported paramagnetic oxygen sensor, without the need to replace, long-term use to save costs
3.)Oxygen, nitrogen, trace proportional valve control, high accuracy, no deviation
4.)USB data print interface, test data can be directly generated EXCEL format
5.)Pedal type test procedure control, complete all the test independentl
6.) Equipped with high temperature and one time shaped quartz glass tube
7.) Equipped with supporting and non supporting specimen holde
8.) Equipped with internal control ignition and hand-held torch two ignition methods
Main configure:
1.) Portable ignition device
2.) Handheld point guns
3.) High temperature resistant quartz glass
4.) Flame height gauge
5.) Control host
Test range | 0-100% |
Work pressure | 0.05-0.3Mpa |
Resolution | 0.1% |
Test precision | ±0.2% |
Steady time | <5s |
weight | 30kg |
Out size | 600*520*600mm |